PDA

View Full Version : VSX-7000 ISDN Issues


satyagolti
03-11-2006, 08:32 AM
Hello

This is Satya from India, my self I'm facing some different kind of configuration Problem while configuring VSX-7000 & S & E models.

the main problem is ISDN Protocol configuration. In India ISDN protocol Standard ETSI Euro ISDN , But some of the systems when we do configuration with above protocol not working. systems are working with only AT&T 5ESS Multipoint or AT&T 5ESS Pt-To-Pt.

when we use AT&T protocol instead of Euro ISDN every 15Min drops the call.

in the same customer campus some systems are working with standard protocol but some systems having problems BRI lines from single telco provider from single switch.

Please help me to solve these issue, any one facing these kind of problem with VSX systems.

Thanks
Satya

senthil
03-12-2006, 07:50 AM
India's standard ISDN switch is EURO/ETSI.If you configure other then this you will get the probelm of disconnecting every 15mins or even it won't work.But the problem seems to be the IMUX softwareis configured as other then Euro/Etsi switch.I faced this smilar problems with Viewstation series.But now i can able to solve this prob.

Senthil.

satyagolti
03-14-2006, 01:59 AM
the thing is when we config this system ETSI EURO ISDN calls not at all connecting.

when we call using ETSI Euro ISDN the problem is Protocal Error Please wait...

please advise is there any software update required

--Satya

xrs
03-15-2006, 03:33 AM
India is using ETSI-EURO ISDN STD. Maybe the IDSN line Voltage is Low coz the line drop. Ask telco provider add booter or extender to the ISDN to make line stable than try to make video call within india. See how?

XRS

Felipe
03-15-2006, 04:58 PM
Hello, i face similar issue, and i discover it was a BRI, and the provider do not make the bonding. I did a lot of test using BRI by BRI, in the local and the remote site, until y discover wich BRI did not work properly, and with that i could argue with the provider.

Felipe
03-15-2006, 05:03 PM
Hello, i face similar issue, and i discover it was a BRI, and the provider do not make the bonding. I did a lot of test using BRI by BRI, in the local and the remote site, until y discover wich BRI did not work properly, and with that i could argue with the provider.

dnshbedi
06-19-2006, 08:51 AM
hiiii,

This isssue we had also faced at one of our sites can u just let me know that who is the line provider. Is it TATA team. let me know then we can look for the solution.

Regards,