brianstabinger
03-05-2008, 01:23 PM
This is in reference to using Crestron's MXP macros to serially control Tandberg's MXP series CODECs.
Requesting/Sorting directory seems to take quite a long time (1 minute? Maybe more...) , during which time using other functions of the macro can lock-up the processor (2-Series, latest firmware). I've been getting around this the cheap-way; by locking-out the macro/video conference functions if/when the directory is being requested or sorted. To increase the stability even more, I've had to set pacing to 5ms on the individual com port.
Again, this just pertains to RS232 control. I can't say for sure if this occurs via TCP/IP.
This is not an issue we've had with Polycom's VSX or even HDX units, but it occurs with any MXP. We can live with it, but it is an annoyance.
Any ideas? Suggestions?
Thanks!
Requesting/Sorting directory seems to take quite a long time (1 minute? Maybe more...) , during which time using other functions of the macro can lock-up the processor (2-Series, latest firmware). I've been getting around this the cheap-way; by locking-out the macro/video conference functions if/when the directory is being requested or sorted. To increase the stability even more, I've had to set pacing to 5ms on the individual com port.
Again, this just pertains to RS232 control. I can't say for sure if this occurs via TCP/IP.
This is not an issue we've had with Polycom's VSX or even HDX units, but it occurs with any MXP. We can live with it, but it is an annoyance.
Any ideas? Suggestions?